Brand Name : Daruifuno

Model Number : DPH790-YD01A

Certification : CE, ISO

Place of Origin : China

MOQ : 1

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 10000 Sets per Month

Delivery Time : 5-25 days

Packaging Details : Carton

Product Name : PH sensor

Electrical Isolation : With Electrical Isolation

Measuring Range : PH: 0~14pH

Operating Temperature : 0.0~50.0℃

Work Pressure : 0~2Bar

Temp. Compensation : Automatic, built-in temperature unit

Calibration Method : Zero position/slope/deviation

Material : ABS

Cleaning : Ceaning interface (Optional)

Protection Grade : IP68

Contact Now

Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring


The digital pH sensor adopts the classic electrochemical principle, which is reliable in measurement and stable in performance. It is widely used in environmental protection water treatment, surface water, purified water, circulating water and other systems, as well as electroplating, electronics, printing and dyeing, chemical, food, pharmaceutical and other process fields. Excellent performance in sewage treatment, drinking water treatment, surface water monitoring, pollution source monitoring, industrial process and other applications.

In order to obtain the best measurement results, regular maintenance is required. Maintenance includes cleaning of electrodes and checking for damage. Check whether the electrode wiring is correct, check the communication setting parameters (address, baud rate, parity bit, stop bit), etc.


Specification:

Model DPH79
Electrical Isolation
Measuring Range PH: 0~14pH TEMP: 0~50℃
Resolution 0.01pH/0.1℃
Accuracy ±0.02pH
Temperature Compensation Automatic, built-in temperature unit
Calibration Method Zero position/slope/deviation
Work Pressure 0~2Bar
Operating Temperature 0.0~50.0℃
Shell Material ABS
Dimension Diameter: 35mm Total length: 260 mm ( include cleaning cover)
Installation Size

1"NPT at both ends of the installation thread;
insertion depth 100 (including cleaning plug 115)

Protection Grade IP68
Weight 150g

Please click the user manual of RS485 pH sensor here:
DPH7 digital pH User Manual.pdf

Features& Advantages

● All-in-one package, can be used with the online transmitters, DTU, and portable instruments
● RS485 interface, Modbus RTU, support access to standard industrial control system
● The protection grade is IP68, can work continuously and stably under water for a long time
● Internal storage of calibration data, support offline calibration, plug and play on site



Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring
Aplication:

Water treatment monitoring
Drinking water,surface water,water quality analyze,ground water,ect.

Industrial process monitoring and dosing control
Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


FAQ
1. What is the measurement principle of this pH electrode?

A: The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.

2. How to judge the pH of the solution?
A: If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.

3. What is the wire length of the pH electrode?
A: The lead wire of this electrode is 1 m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

4. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.

Product Tags:

Aquaculture Fisheries PH ORP Probe

      

Freshwater Farming PH ORP Electrode

      

Cooling Circulating Water PH Sensor

      
China Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring wholesale

Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Suzhou Delfino Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0